Align the first metal roofing panel so that it overlaps the edging by 1 2 to 3 4 of an inch and is square to the roof line.
Sheet metal roof installation instructions.
Be sure the larger edge is laid so that the small edge of the next panel will overlap it.
5install metal panels or shingles.
Today we will install an american building components sl 16 metal roofing panel.
Tile sheets have to be laid from right to left sequence starting on the right hand side of the roof laying on the next sheet to the left lapping over the profile with the small gully detail on the last lap of the left of the sheet.
These instructions specifically focus on metal panel installation.
Use your neoprene washer head screws to secure the metal to the sheathing.
Space the screws about 12 in 30 cm apart down the entire piece of metal.
Lay and secure the first metal panel.
If a two sheet run is required lay the sheets in this position and use the same fixing instructions as above.
Finish the first side of the roof.
Lay the roofing felt.
The eight step installation instructions below will show you how to install metal roofing panels as a weekend diy project for your home.
Copper or stainless steel is recommended lock and seal all joints solder joints on slopes less than 3 12.
2 corrugated metal roof installation instructions.
To learn more about eave trim and cleat installation view our other how to videos.
Take care the first piece is aligned precisely perpendicular square to the edge.
Installation of panels roof pitch this style of metal roofing panels requires a certain degree of pitch to ensure proper water drainage.
Learn how to install our metal roof panels by watching the short video or reading the transcript below.
Flat seam roofs used in low no slope areas or areas subject to flooding or standing water typically made from 20 x 28 sheets relative geometry is important fro expansion and contraction sheet use efficiency and wind load.
Take your first sheet of metal and place it on the roof so that it overhangs the edge at least 3 4 in 1 9 cm.
Buy the metal panels.
One downside is that the metal sheets have a susceptibility to denting both in installation and during hailstorms.
Install the roofing screws vertically along each rib in the panel.
Florida building code allows a minimum pitch of 2 12 for grand rib 3 panels as long as lap screws and sealant are applied to the laps to prevent water from siphoning over the ribs see fig.
A corrugated metal roof is quieter than pvc when it rains.